Renewable Design for Condensing Unit Cold Room - 4DC-5.2-40P 5HP CONDENSING UNIT – Cooler
Renewable Design for Condensing Unit Cold Room - 4DC-5.2-40P 5HP CONDENSING UNIT – Cooler Detail:
Company Profile

Product Description


|
Model |
4DC-5.2-40P |
|
Horse power: |
5HP |
|
Cooling capacity: |
3-17.65KW |
|
Displacement: |
26.8CBM/h |
|
Voltage: |
Customize |
|
Refrigerant: |
R404a/R134a/R507a/R22 |
|
Temperature: |
-30℃– -15℃ |
|
Motor power |
3.8kw |
|
Unit Standard Configuration Table |
|
|
Spare Parts/Models |
|
|
Condenser(cooling Area) |
60㎡ |
|
Refrigerant Receiver |
√ |
|
Solenoid valve |
√ |
|
Oil Separator |
√ |
|
High/Low pressure meter Plate |
√ |
|
Pressure control switch |
√ |
|
Check valve |
√ |
|
Low pressure meter |
√ |
|
High pressure meter |
√ |
|
Copper Pipes |
√ |
|
Sight Glass |
√ |
|
Filter Drier |
√ |
|
Shock tube |
√ |
|
Accumulator |
√ |
|
Model |
Condensing temperature ℃ |
Cooling capacity Qo (Watt) power consumption Pe(KW) |
||||||||||||
|
Evaporation temperature ℃ |
||||||||||||||
|
|
12.5 |
10 |
7.5 |
5 |
0 |
-15 |
-10 |
-15 |
-20 |
-25 |
-30 |
|||
|
4DC-5.2Y |
30 |
Q |
24600 |
22450 |
20400 |
18510 |
15140 |
12250 |
9790 |
7700 |
5930 |
4440 |
3210 |
|
|
|
P |
3.61 |
3.55 |
3.49 |
3.42 |
3.26 |
3.08 |
2.86 |
2.62 |
2.35 |
2.05 |
1.72 |
||
|
40 |
Q |
21700 |
19750 |
19740 |
16270 |
13260 |
10690 |
8480 |
6610 |
5030 |
3700 |
2600 |
||
|
|
P |
4.30 |
4.21 |
4.12 |
4.02 |
3.79 |
3.53 |
3.23 |
2.91 |
2.56 |
2.17 |
1.75 |
||
|
50 |
Q |
18880 |
17170 |
15580 |
14110 |
11460 |
9190 |
7240 |
5590 |
4190 |
3020 |
2050 |
||
|
|
P |
4.96 |
4.84 |
4.71 |
4.57 |
4.27 |
3.93 |
3.56 |
3.15 |
2.71 |
2.23 |
1.73 |
||
|
Cooling capacity Qo (Watt) power consumption Pe(KW) |
||||||||||||||
|
Evaporation temperature ℃ |
||||||||||||||
|
|
|
7.5 |
5 |
0 |
-5 |
-10 |
-15 |
-20 |
-25 |
-30 |
-35 |
-40 |
-45 |
|
|
30 |
Q |
|
|
|
21100 |
17420 |
14220 |
11470 |
9100 |
7080 |
5370 |
3930 |
|
|
|
|
P |
|
|
|
5.52 |
5.29 |
4.99 |
4.62 |
4.18 |
3.70 |
3.19 |
2.66 |
2730 |
|
|
40 |
Q |
|
|
|
17650 |
14520 |
11810 |
9460 |
7440 |
5720 |
4250 |
3010 |
2.11 |
|
|
|
P |
|
|
|
6.34 |
5.95 |
5.50 |
4.99 |
4.43 |
3.83 |
3.22 |
2.60 |
1980 |
|
|
50 |
Q |
|
|
|
14300 |
11730 |
9490 |
7550 |
5880 |
4440 |
3220 |
2190 |
1.98 |
|
|
|
P |
|
|
|
7.07 |
6.53 |
5.93 |
5.29 |
4.62 |
3.92 |
3.22 |
2.52 |
||
Noted: Condensing unit without Refrigerant,When the unit is commissioned, the refrigerant is injected by professional technicians
Advantages

Advantages

Application

Product Structure

Product detail pictures:
Related Product Guide:
We're committed to furnishing easy,time-saving and money-saving one-stop purchasing support of consumer for Renewable Design for Condensing Unit Cold Room - 4DC-5.2-40P 5HP CONDENSING UNIT – Cooler , The product will supply to all over the world, such as: Germany, Spain, Finland, Corporate goal: Customers' satisfaction is our goal, and sincerely hope to establish long-terms stable cooperative relations with customers to jointly develop the market. Building brilliant tomorrow together!Our company regards "reasonable prices, efficient production time and good after-sales service" as our tenet. We hope to cooperate with more customers for mutual development and benefits. We welcome potential buyers to contact us.